CUSTOMER SUPPORT
Master-Bilt & LEED
Master-Bilt provides walk-in coolers and freezers that meet the U.S. Green Building Council's LEED prescriptives as outlined below.
ITEM | ATTRIBUTE | PRESCRIPTIVE MEASURE | BASELINE FOR ENERGY COST BUDGET | MASTER-BILT |
---|---|---|---|---|
Envelope | Freezer insulation | R-46 | R-36 | YES |
Cooler insulation | R-36 | R-20 | YES | |
Automatic closer doors | Yes | No | YES | |
High efficiency low/no heat reach-in doors | 40 W/ft. of door frame (low temperature) 17 W/ft. of door frame (medium temperature) | 40 W/ft. of door frame (low temperature) 17 W/ft. of door frame (medium temperature) | YES | |
Evaporator | Evaporator fan motor and control | Shaded pole and split phase motors are prohibited. Use PSC or EMC motors. | Constant speed fan | YES |
Hot gas defrost | No electrical defrosting | Electric defrost | YES | |
Condenser | Air-cooled condenser fan motor and control | Shaded pole and split phase motors are prohibited. Use PSC or EMC motors. Add condenser fan controllers | Cycling one speed fan | YES |
Air-cooled condenser design approach | Floating head pressure controls or ambient subcooling | 10° F to 15° F dependent on suction temperature | YES | |
Lighting | Lighting power density (W/sq. ft.) | 0.6 W/sq. ft. | 0.6 W/sq. ft. | YES |